Manitowoc Ice Ice Maker K00042 User Manual

K00042 STACKING KIT  
Installation Instructions  
The K00042 stacking kit is used for stacking a G-0600 ice  
Installing the Ice Chute  
machine on an E-1100 ice machine. The bin must be leveled  
before proceeding.  
Installing the E-1100 Ice Machine  
1. See service manual for uncrating and inspection of ice  
machine.  
1. Attach bottom mounting bracket from kit to the front base  
channel of the E-1100 using two #10-24 x 5/8” long sheet  
metal screws provided (see Illustration 2 and 3).  
2. Remove angle “A” from upper G-0600 (see Illustration  
2).  
2. Remove top cover and side panels from ice machine.  
3. Set ice machine carefully and squarely on bin.  
4. Position top cover from kit on right-hand side of ice  
machine. Position left-hand top cover. Attach water  
shield to right-hand top cover on flange with one #8 x  
1/2” long sheet metal screw from kit (see Illustration 1).  
5. Apply foam tape from the kit, as shown in Illustration 1.  
Installing the G-0600 Ice Machine  
1. See service manual for uncrating and inspection of ice  
machine.  
2. Remove top cover and side panels from ice machine.  
3. Set G-0600 on top of E-1100 with backs of both  
machines being flush.  
3. Attach top mounting bracket from kit to top rail of E-  
1100 using existing screw.  
4. Reattach angle “A” to G-0600.  
5. From the upper ice machine, carefully bring the ice chute  
down in place until the weld studs located on the ice  
chute go through the slotted holes in the bottom mounting  
bracket. Secure with four wing nuts provided in the kit.  
6. Check for free movement of the water curtains on both  
the G-0600 and E-1100 ice machines (styrene covers over  
evaporators).  
7. Reattach all panels of both ice machines.  
8. Proceed to ice machine service manuals for electrical and  
water hook-ups and start-up procedure.  
4. Remove screw from rear panel of G-0600 and screw from  
E-1100 in area of electrical hook-up (rear panel). Apply  
rear-locking plate using existing screws that were  
removed. With offset rear locking plate fastened, the left  
and right side of the G-0600 should be sitting on the E-  
1100 top covers, as shown in Illustration 2.  
5. Before applying RTV sealant in designated areas to insure  
against leaks or water hang-up, as shown (Illustration 2),  
remove the water pump, water curtain, and water trough.  
After sealing the seams with RTV, replace the water  
pump, etc.  
Parts List  
Qty.  
Description  
Part No.  
1
2
#8 x 1/2” lg. Sheet Metal Screw......5121531  
#10 -24 x 5/8” lg. Sheet Metal  
Screw...............................................5202053  
#8-32 Wing Nut ..............................5489021  
Top Mounting Bracket ....................6625414  
Bottom Mounting Bracket...............6606514  
Water Shield....................................6625114  
Top Cover .......................................6852514  
LH Top Cover .................................6625314  
Ice Chute .........................................6625214  
Rear Locking Plate..........................6242914  
4
1
1
1
1
1
1
1
Manitowoc Ice, Inc.  
2110 South 26 Street, P.O. Box 1720, Manitowoc, WI 54221-1720 USA  
8002033  
Telephone 920-682-0161, Fax - Sales: 920-683-7589, Service/Parts: 920-683-7585, Other: 920-683-7879  
Rev. 05/16/01  
 

KWC Plumbing Product K20H360000A22 User Manual
La Crosse Technology Portable Radio WD 3106UR B User Manual
Lennox International Inc Furnace G24M SERIES User Manual
LG Electronics Computer Monitor W2254TQ User Manual
Life Fitness Elliptical Trainer 95XE 0XXX 02 User Manual
Linksys Network Card WAP4400N User Manual
Lochinvar Boiler CB 0495 User Manual
LSI Network Card 20160 User Manual
Makita Cordless Saw JV100D User Manual
Mercedes Benz Automobile 2001 E Class Wagon User Manual