Lincoln Electric Welding Consumables 308 User Manual

Date:  
MSDS No.:  
11/12/2008  
CAN-M460-C  
Trade Name:  
Sizes:  
Blue Max Manual Electrodes  
All  
11/15/06  
Supersedes:  
M A T E R I A L S A F E T Y D A T A S H E E T  
For Welding Consumables and Related Products  
Conforms to Workplace Hazardous Materials Information System (WHMIS) Rev. November, 1988  
Section I & II - Preparation and Product Information  
Covered Electrode  
Product Type:  
Products:  
Blue Max  
308/308L AC-DC  
309/309L AC-DC  
347 AC-DC  
The Lincoln Electric Company of Canada LP  
179 Wicksteed Avenue  
Toronto, Ontario M4G 2B9 CANADA  
Phone: (416) 421-2600  
316/316L AC-DC  
2100  
Prepared by The Lincoln Electric Company, Cleveland, Ohio, USA  
(216) 481-8100, on the date shown above.  
Section III - Hazardous Ingredients (1)  
I M P O R T A N T !  
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal use of this  
product are covered by Section VII; see it for industrial hygiene information.  
CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes.  
(1)  
The term “hazardous” in “Hazardous Ingredients” should be interpreted as a term required and defined in the Hazardous Products Act and  
does not necessarily imply the existence of any hazard.  
TLV  
LD50  
LC50 mg/m3  
Ingredients:  
Titanium dioxides  
CAS No. Wt. % mg/m3 (Route/Species) (Route/Species)  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
2.3 LCLo  
13463-67-7  
1332-58-7  
7440-47-3  
1317-65-3  
1344-09-8  
7439-89-6  
65996-74-9  
7439-96-5  
14808-60-7  
7789-75-5  
7440-03-1  
7440-48-4  
7440-02-0  
7439-98-7  
554-13-2  
10-30  
5-10  
1-5  
10  
5**  
0.5(b)  
10  
590 g/kg LDLo  
Mineral silicates  
(oral/rat) reproductive  
2.16 mg/kg LDLo  
(intravenous/rat)tumorigenic  
Chromium and chromium alloys or compounds (as Cr)  
Not Available  
Limestone and/or calcium carbonate  
1-5  
1153 mg/kg  
Silicates and other binders  
1-5  
10*  
10*  
5
(oral/rat)  
Not Available  
Iron  
1-5  
Not Available  
Iron oxides  
1-5  
9 g/kg  
Manganese and/or manganese alloys and compounds (as Mn)  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.1-1  
0.2  
(oral/rat)  
(inhalation/human)  
200 mg/kg LDLo  
300 LCLo  
Quartz  
#0.05**  
2.5  
(intratracheal/rat)  
(inhalation/human)  
Not Available  
4250 mg/kg  
Fluorides (as F)  
(oral/rat)  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
Not Available  
Niobium alloys (as Nb) (347 type only)  
Cobalt  
10*  
.02  
6170 mg/kg  
(oral/rat)  
50 mg/kg LDLo  
Nickel (metal)  
(2100 type only)  
1.5  
(intravenous/mouse)  
114 mg/kg LDLo  
Molybdenum alloys (as Mo) (316 type only)  
Lithium compounds (as Li)  
10  
(intraperitoneal/rat)  
4111 mg/kg LDLo  
10*  
(oral/human)  
Stainless steel core wire  
Nominal core wire composition:  
Chromium  
60-100  
2.16 mg/kg LDLo  
7440-47-3  
7440-02-0  
7439-98-7  
7439-96-5  
7439-89-6  
20-30  
10-13  
2.5  
2.0  
bal.  
0.5(b)  
1.5  
10  
0.2  
10*  
Not Available  
Not Available  
(intravenous/rat)tumorigenic  
50 mg/kg LDLo  
Nickel  
(intravenous/mouse)  
114 mg/kg LDLo  
Molybdenum  
Manganese  
Iron  
(316 type only)  
Not available  
2.3 LCLo  
(inhalation/human)  
(intraperitoneal/rat)  
9 g/kg  
(oral/rat)  
Not Available  
Not Available  
Notes:  
(*)  
(LDLo, LCLo) Lowest published toxic concentration.  
Not listed. Nuisance value maximum is 10 milligrams per cubic meter.  
TLV value for iron oxide is 5 milligrams per cubic meter.  
(b)  
(#)  
The OSHA PEL for chromium (VI) is 5 micrograms (0.005  
milligrams) per cubic meter. The TLV for water soluble  
chromium (VI) is 0.05 milligrams per cubic meter and the  
TLV for insoluble chromium (VI) is 0.01 milligrams per  
cubic meter.  
(**)  
As respirable dust.  
Crystalline silica (quartz) is on the IARC (International  
Agency for Research on Cancer) and NTP (National  
Toxicology Program) lists as posing a carcinogenic risk to  
humans.  
Section IV - Physical Data  
Physical data such as odor, vapor pressure, density, evaporation rate and freezing or boiling points are not listed as they are not applicable  
to this product and its use.  
Section V - Hazard Data  
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See CSA W117.2 Section 9.7 as referenced in  
Section VIII. Product is inert, no special handling or spill procedures required.  
Rev 9/07  
(CONTINUED ON SIDE TWO)  
 

Laser MP3 Player MP4 P13 User Manual
LG Electronics Clothes Dryer DLE0442 User Manual
LG Electronics Flat Panel Television 141K TX User Manual
LG Electronics Washer WM3001HPA User Manual
Link electronic Universal Remote PSR 826 User Manual
LOREX Technology DVR L20WD800 User Manual
Lux Products Thermostat PSMH45 User Manual
Makita Drill DA4030 User Manual
Makita Pole Saw 4604D User Manual
Meade Telescope 90AZ ADRB User Manual