Lightolier Indoor Furnishings VPA1G12PR132 User Manual

VP PARABOLIC VPA1G12PR132  
Page 1 of 2  
1'x4' RECESSED FLUORESCENT, 3" DEEP, 12 CELL (1 ROW) PARABOLIC LOUVER  
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR INTENSE VDT USE (PREFERRED)  
Features  
• Meets IES RP1 for lighting VDT areas with intense use.  
• 72.0% efficient (T8).  
• 1.6 spacing mounting ratio.  
• Specular, low iridescence, pre-anodized aluminum louver.  
• Vertical grain on louver eliminates reflected lamp image on cross  
baffle.  
• Louver frame with positive light stop.  
• Spring loaded latches (self centering).  
• Reversible louver hinging.  
• Louver has protective dust guard.  
• Only 6-5/8" deep body.  
• Black housing exterior for cooler ballast operating temperature.  
• Turned-in edges for safe handling.  
• Built-in earthquake clip (pat. no. 5,072,344).  
• UL-Listed twin knockout access plate.  
• Air closure strips (optional).  
• Construction to meet NYC Code or Chicago Plenum is available.  
MOUNTING METHODS  
DIMENSIONS  
exposed T-grid ceiling.  
exposed slot T-grid ceiling.  
G
T
Semi-specular  
aluminum  
Exposed slot  
T-bar by others  
6-1/2"  
(165mm)  
1/4" max.  
1-1/2" max.  
1-1/2" max.  
Acoustical  
Acoustical  
material  
by others  
material  
by others  
12"  
(305mm)  
15/16" or 1"  
9/16"  
12"  
12"  
Exposed T-bar  
by others  
plaster ceiling/flanged.  
direct concealed two directional  
T-grid ceiling.  
F
T
1-1/8" min  
3-3/4" max.  
Plaster  
Opening  
12-1/8"  
1/4" max.  
Plaster frame  
must be  
ordered  
separately  
1-7/8"  
max.  
Plaster  
by others  
Acoustical  
material  
by others  
13/16"  
3/8"  
Aluminum  
12-11/16"  
12"  
flange trim  
Job Information  
Type:  
Job Name:  
Cat. No.:  
Lamp(s):  
Volts/Ballast:  
earthquake clip  
before  
earthquake clip  
installed  
installation  
Lightolier a Genlyte Thomas Company  
Technical Information: (978) 657-7600 • Fax (978) 658-0595  
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710  
We reserve the right to change details of design, materials and finish.  
© 2002 Genlyte Thomas Group LLC (Lightolier Division)  
A0902  
SECTION 2/Folio G05-10 REV. A  
 

Kuppersbusch USA Refrigerator IKE339 1 User Manual
Land Pride Lawn Mower ZT60 Series User Manual
Lenovo Computer Keyboard SK 8855 User Manual
Lexmark All in One Printer 90T4110 User Manual
LG Electronics Computer Monitor W2254TQ User Manual
LOREX Technology Switch SHS 2SA User Manual
Makita Grinder GE0600 User Manual
Mark Levinson Stereo Amplifier No 33H User Manual
MartinLogan Speaker CW10 User Manual
Maytag Clothes Dryer MED5900TW1 User Manual