Lightolier Indoor Furnishings 1000ICV User Manual

Lytecaster® Recessed Downlighting  
1000ICV  
Page 1 of 1  
5" Aperture Incandescent Insulated Ceiling Frame-In Kit  
8
Complete Fixture consists of Reflector Trim & Frame-In Kit. Select each separately.  
Frame-In Kit  
Reflector Trims — See Individual Reflector Trim Specification Sheets  
Adjustable  
Pinhole  
1052LV  
1000ICV  
Baffles  
Aperture Cone  
Elbow  
1055LV  
1063LV 1064WDLV  
1064LV 1064WDPLV  
1056LV  
1062LV  
1055WHLV  
1064CDLV  
Features  
Options & Accessories  
Mounting Bars:  
Plaster Ceiling Ring:  
Extra-Thick Ceiling  
Mounting Ring:  
1. Housing: .026" (#20 ga.) galvanized steel. U.L. listed for direct contact with  
thermal insulation. Access door for inspection of junction box.  
2. Mounting Frame: .036” (#20 ga.) galvanized steel. Accommodates all  
ceilings up to 1” thick. Four slots are positioned 90º apart to simplify  
alignment. Push-in/twist-out rotoclips hold reflector flush to ceiling.  
3. Junction Box: 2” x 4” x 4”, .063” (#14 ga.) galvanized steel. U.L. listed for,  
maximum of 6 No. 12 ga., 90º C through branch circuit conductors. Quick  
release “L” shaped cover for outside access to wiring. Access door inside of  
housing allows easy inspection of wiring without removal of housing. Integral  
cable clamps permit attachment of nonmetallic Romex® or armored cable  
without the need for additional connectors.  
1964 - 20" set of (2)  
1960 - 7/8" depth for wet plaster ceilings.  
1967B - up to 2" thick ceilings.  
1975A  
1956 set of (4)  
MR-16 Socket Replacement:  
J-Bar Ceiling Clips:  
Labels  
UL (Type I.C., Suitable for Damp Locations), I.B.E.W.  
Romex® is a registered Trademark of General Cable Industries Inc.  
US Patent No.: 4,313,154; 5,045,985; 4,751,624  
4. Mounting Bars: .059” (#16 ga.) galvanized steel. 13” long bars extend to  
27, rotatable and lockable, with integral T-bar tabs. Attach to wood joist or  
T-bar ceilings without need of accessories.  
5. Socket Housing: .036” (#20 ga.) galvanized steel.  
6. Socket: Field replaceable. Two pin socket, pre-wired with #18 SF1 leads to  
junction box.  
7. Thermal Protector: Meets NEC and U.L. requirements. Located inside  
housing.  
8. Transformer: Mounted inside, magnetic, 120V primary, norminal 12V  
secondary. Removable from below.  
Job Information  
Type:  
Job Name:  
Cat. No.:  
Lamp(s):  
Notes:  
Dimming  
Dimming Controls: Use only dimmers specifically designed for use with magnetic  
transformers, like Lightolier Onset, Sunrise series LV or VA, dimmers, or any  
Lightolier Controls dimming system. Low voltage fixtures may produce audible  
sound when used with dimmers, which may be objectionable in acoustically criti-  
cal areas.  
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710  
We reserve the right to change details of design, materials and finish.  
Lightolier is a Philips group brand  
 

Life Fitness Stepper Machine clsxh oxxx 02 User Manual
Little Wonder Blower 2 1 1960 User Manual
Magnat Audio CD Player MC 1 User Manual
Makita Air Compressor MAC1200 User Manual
Makita Drill 7104L User Manual
Makita Saw 5620DWA User Manual
Manfrotto Camcorder Accessories ART 190CXPRO3 User Manual
Metabo Power Hammer 600224420 User Manual
Metrologic Instruments Scanner MS2221 User Manual
Meyer Sound Speaker UMS SM User Manual