LG Electronics Digital Camera iCAM4100 User Manual

Quick Start Guide  
FOR MODEL NUMBERS:  
iCAM4100  
iCAM4100R  
iCAM4101  
iCAM4101R  
iCAM4110-E1  
iCAM4110R-E1  
iCAM4110-H1  
iCAM4110R-H1  
iCAM4111-E1  
iCAM4111R-E1  
iCAM4111-H1  
iCAM4111R-H1  
C O P Y R I G H T  
©
2 0 0 7 L G E L E C T R O N I C S U S A I N C , A L L R I G H T S R E S E R V E D .  
LG IrisAccess™ 4000: iCAM4100 Quick Start Guide  
The content of this document is furnished for informational use only, is subject to change without notice, and should not be construed as a commitment by LG Electronics USA  
Incorporated. LG Electronics USA Incorporated assumes no responsibility or liability for any errors or inaccuracies that may appear in the informational content contained in this document.  
Please remember that existing images or drawings that you may want to include in your document may be protected under copyright law. The unauthorized incorporation of such material  
into your work could be a violation of the rights of the copyright owner. Please be sure to obtain any permission required from the copyright owner.  
LG, LG Iris, the LG logo, LG Iris logo and IrisAccess are either registered trademarks or trademarks of LG Electronics Incorporated in the United States and/or other countries.  
LG Electronics USA Incorporated, Iris Technology Division. 7 Clarke Drive, Cranbury, New Jersey 08512, USA.  
Document Number: DV002Q502 (07/07)  
 
iCAM4100 in the IrisAccess System  
2
Ethernet  
Door Control  
RS-422 Serial  
Netw ork Sw itch  
ICU  
DCU  
The iCAM4100 is a two-eye iris camera used to capture the iris images of the user. The iCAM includes an  
alignment indicator behind the mirror and voice prompts to assist the user. A Vacuum Fluorescent Display (VFD)  
displays system time, date, and user guidance. When used in a typical access control application, the iCAM is  
placed near the secured portal to provide user identification. The optional keypad can be used for a PIN  
verification mode.  
The iCAM can be used in enrollment mode using the IrisEnroll application (included with EAC software) or  
recognition mode when it is configured for use with an ICU. The iCAM can not easily be switched between  
enrollment and recognition modes once configured.  
The iCAM can be wall mounted or used with an optional desk-top stand.  
iCAM4100 Model Variations  
Smartcard Reader  
VFD  
RoHS compliant  
Keypad  
HID iClass  
IE Smart-ID  
iCAM4100  
iCAM4100R  
iCAM4101  
iCAM4101R  
iCAM4110-H1  
iCAM4110R-H1  
iCAM4110-E1  
iCAM4110R-E1  
iCAM4111-H1  
iCAM4111R-H1  
iCAM4111-E1  
iCAM4111R-E1  
 
Installation Requirements  
3
bottom of  
mirror  
61”  
(155mm)  
55”  
(140mm)  
floor  
• The recommended mounting height for the iCAM4100 is 140cm (55 inches) from the floor to the bottom of the  
unit. This mounting height can be adjusted to accommodate the average user height at the installed location.  
• High amounts of ambient light must be avoided. Intense light sources such as sunlight or halogen lamps may  
reduce the image capture performance of the iCAM, this may result in an increased “failure to acquire” rate.  
• The iCAM is not weatherproof and must not be exposed to precipitation or extreme temperatures. An enclosure  
• All system components including the Ethernet network must be powered through Uninterruptible Power Supplies  
(UPS). UPS must provide power line filtering as well as power back-up operation.  
• Each IrisAccess™ system component on the Ethernet network system must have a unique manually assigned IP  
address.  
The iCAM4100 requires at least the following wires:  
• Ethernet network wiring to connect with the network switch to communicate to the IrisServer or an ICU.  
* Note: For systems consisting of only an IrisServer and iCAM may use an Ethernet crossover cable to connect  
the iCAM directly to the IrisServer computer.  
• Power (12VDC +/-10% and 2.5Amps MAX)  
IMPORTANT: IT IS RECOMMENDED TO USE THE POWER ADAPTER SUPPLIED WITH THIS PRODUCT. AN OVER OR  
UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY.  
 
iCAM4100 Installation  
4
1. Remove the three security screws (use included security bit wrench) from the bottom of the iCAM.  
Front  
Back  
2. While gently pulling the cover upward, pull forward simultaneously.  
Screw to fix the plate  
2
1
3. Unscrew the installation plate screw and slide the body of iCAM4100 upward to separate from the installation  
plate.  
4. Position the installation plate on the desired wall near the secured door and mark the holes as the figure below  
illustrates. The recommended height from the floor to bottom of unit is 140cm (55”), however installation height  
can be adjusted depending on average height of users.  
5. In case of recessed mounting, leave 6mm (1/4”) of extra space above the marked hole when mounting the  
installation plate to allow the iCAM to slide down onto the installation plate tabs.  
 
iCAM4100 Installation (contd)  
5
196  
5
<hole>  
6.4801  
156  
15  
16  
Hole  
6
45  
2.2  
7.6  
Dimensions and Screw Holes in the Installation Plate (mm unit)  
80  
62.8  
35.5  
11  
2.2  
1
Installation Plate  
Rotation Part with Front Enclosure  
Dimensions of iCAM4100 (mm unit)  
 
iCAM4100 Installation (contd)  
6
6. Route the power line, network line, and other necessary cables through the installation plate hole.  
7. Using the appropriate fasteners for the material in which the iCAM will be mounted, secure the installation plate.  
8. Slide the iCAM4100 body into the installation plate and fasten it with the retaining screw.  
9. Attach the wires from the 12VDC power supply to the screw terminal connections. The +12VDC (white wire)  
power connects to the + (positive) terminal, whereas the 12VDC ground (black wire) connects to the – (negative)  
terminal.  
* Note: If it is required to extend the length of the wires from the power adapter to the iCAM, refer to the  
Power Input  
Wiegand IN  
Wiegand OUT  
1
Serial RS-232/422/485  
1
1
GND VCC  
Reset  
(Unused)  
(Unused)  
LAN  
(Unused)  
1
1
SmartCard  
Reader  
General  
Purpose I/O  
1
Keypad Input  
Tamper SW  
10. Connect the CAT5/RJ45 network wire into the LAN port of the iCAM. Make sure that the RJ45 connector locks  
securely into the LAN port.  
11. Wiegand device such as proximity card reader and smart card readers may be connected to the iCAM through  
the Smart Card or Wiegand In connections. Refer to the 4000 Hardware Manual for connection details.  
(Note: Only the smart card [serial] and Wiegand input interfaces are active with the current iCAM versions.)  
* Note: The iCAM4110-H1, iCAM4111-H1 and the iCAM4110-E1, iCAM4111-E1 are supplied with a smart card  
reader already wired and installed.  
12. Close the front cover and gently slide the cover downwards. Fasten with front cover using the three security screws.  
* Note: The iCAM includes two tamper switches. One switch is located on the rear of the iCAM to detect removal  
from the wall or enclosure from which it is installed. A second tamper switch is located behind the front  
plate to detect tampering with the front of the unit. During installation be sure that the rear tamper switch  
is in a position which can detect unit removal from the wall or enclosure.  
 
iCAM4100 Configuration  
7
Changing the IP Address of the iCAM  
* Note: The IP Address of each iCAM must be changed individually. Do not connect more than one  
un-configured iCAM to the network at any one time to avoid IP Address conflicts.  
Any computer with a web browser which supports graphics (ex. Internet Explorer) can be  
used to configure the iCAM4000/4100.  
1. Set the computer to the static IP of 192.168.5.1 - subnet 255.255.255.0  
screen will appear.  
3. Enter the default Username: iCAM4000 and Password: iris4000 (both are case sensitive)  
4. The iCAM Configuration Main Menu will appear.  
 
iCAM4100 Configuration (contd)  
8
5. Select Network Settings.  
6. Enter the new IP address for the iCAM (default = 192.168.5.100)  
7. Enter the new Subnet Mask for the iCAM (default = 255.255.255.0)  
8. Enter the new Broadcast Address for the iCAM (default = 192.168.5.255)  
9. Enter the new Default Gateway for the iCAM. (default = 192.168.5.254)  
10. Click OK to save changes and to open network settings verify screen.  
If the new iCAM IP address is still on the same subnet as the computer:  
- after 10 seconds the web browser will resolve to the new IP address and the login screen will appear again.  
If the new iCAM IP Address is on a different subnet:  
- the web browser will display the standard “The page cannot be displayed” message.  
To test the IP Address change, perform a ping to the new IP Address.  
1. Click on Start (in the Windows task bar)  
2. Select Run  
3. Type cmd  
4. Press Enter  
5. At the command prompt type: ping <new IP> (ex. ping 192.168.5.120)  
6. Close the command prompt window.  
If changing the IP Address to multiple iCAMs  
* Note: After each iCAM configuration the arp cache on the computer must be deleted.  
1. Click on Start (in the Windows task bar)  
2. Select Run  
3. Type cmd  
4. Press Enter  
5. At the command prompt type: arp –d  
6. Close the command prompt window.  
7. Connect the next iCAM to be configured on the network and perform the configuration to the next iCAM.  
 
iCAM4100 Configuration (contd)  
9
Once all iCAMs have been configured  
Once all iCAMs have been configured, the computer IP Address can then be changed back to its original IP Address  
or to the new IP Address as required to communicate to the rest of the IrisAccess™ system.  
SmartCard Integration  
The iCAM4010-E1 and iCAM4010R-E1 have a built-in Integrated Engineering Smart ID smart card reader, and  
the iCAM4010-H1 and iCAM4010R-H1 have a built-in HID iClass smart card reader.  
The only configuration to the iCAM for smart card support is to enter an “Air-link” Encryption key or Application  
key. This key is used to lock / unlock access to the smart card data. Once changed the iCAM will write all cards  
with this key (enrollment) and will only be able to read cards with this key (verification).  
To configure the smart card key; log into the iCAM configuration interface (see “Changing the IP Address of the  
iCAM” in section 6).  
From the main menu select “SmartCard Configuration”.  
• Leave the “Serial Port” selection as Serial-Port-2.  
• Select the “Smart Card Type”; HID iClass (iCAM4010-H1), MIFARE, or Smart ID (iCAM4010-E1).  
• Enter the Application Key (Air-Link Key) in Hexadecimal format.  
* Note: “Set to Default” will reset the Application Key to the HID iClass default.  
• OK must be clicked for the changes to be entered.  
• To complete the smart card integration in the IrisAccess system, the IrisServer, IrisEnroll software and ICUs must  
be configured. Refer to the 4000 Smart Card Integration document located on the EAC software CD for more  
information.  
 
Technical Support  
10  
Technical Support  
Additional information and Technical assistance is available on the LG Electronics – Iris Technology Division’s support  
web site at www.lgiris.com, click on Support & Service then Technical Support.  
 

Lanier Printer Accessories 480 0083 User Manual
Lightolier Work Light FBP750 4P User Manual
Lowrance electronic GPS Receiver 540c Baja User Manual
Makita Nail Gun AN923 User Manual
Makita Power Screwdriver 6820V User Manual
Melissa Microwave Oven 753 094 User Manual
Melissa Styling Iron 635 124 User Manual
Memorex Stereo System MX4139 User Manual
Memorex Universal Remote URC 4880 User Manual
Metra Electronics Car Stereo System AFDI RSE 01 User Manual